구조물 기둥 내진 보강 성능 평가 |
이용교, 박연준, 박인준, 박승희 |
|
Performance Evaluation of Seismic Reinforced Column of Buildings |
Youngkyo Lee, Yoen-Jun Park, Inn-Joon Park, Seunghee Park |
|
|
|
Abstract |
It have been increasing societal and economic demands on seismic design and retrofit because of recently frequent occurrence of earthquake in Korea. Structural collapse due to the earthquake results from the failure of columns and hence the columns have to be reinforced to improve the seismic performance of the structures. In this study, new seismic retrofit method for columns of buildings was proposed so that the bottom part and the base of the columns could be reinforced with steel plates and fire-proof rubber pads. Statical loading tests were performed with the columns to evaluate the seismic performance of the proposed retrofit method. The failure mode and the strain variation of the reinforced column were analyzed according to the static loading and the results were compared to those from the unreinforced column. As a result, the seismic performance of the reinforced column was significantly improved. |
Key Words:
Steel plate reinforcement; Seismic performance; Static loading test; Strain variation; Failure mode |
요지 |
최근 국내의 지진 빈도가 증가하고 있는 반면, 기존 구조물의 대부분이 내진 설계에 따라 설계되지 않았으므로 지진 발생 시에 생겨날 수 있는 사회-경제적 문제가 우려된다. 지진 발생 시, 구조물의 붕괴는 주로 기둥의 파괴에 원인을 두고 있기 때문에, 기둥의 내진 보강과 보강 성능 평가의 적용이 시급하다. 본 연구에서는, 기둥의 하단부과 기초를 강판과 내화성 고무 패드로 보강한 기둥의 내진 보강 성능 평가를 시행하기 위해 기둥 모형 실험체를 제작하고 해당 실험체에 내진 보강을 하여 정적 가력 시험을 수행하였다. 실험 결과를 바탕으로 기둥의 횡력에 대한 파괴모드의 유형을 분석하였고, 부재의 변형률 변화 특성을 검토하였으며, 기존 철근 콘크리트 기둥과 비교한 결과, 내진 보강된 기둥의 내하력이 전반적으로 향상되었음을 알 수 있었다. 결과적으로, 위의 과정을 통하여 기둥의 내진 성능이 상당부분 향상된 것을 확인하였다. |
핵심용어:
강판보강; 내진성능; 정적가력실험; 변형률변화특성; 파괴모드 |
|