모듈화 구조에서 원사이드 볼트를 이용한 보-기둥 접합부의 성능평가실험 |
오명호, 박성진 |
|
The Experiment for Performance Evaluation of Beam-Column Connections in the Modular Structures |
Myoung Ho Oh, Sung Jin Park |
|
|
|
Abstract |
This paper was described to perform cyclic load tests for evaluating the performance of the light-weight beam and the rectangular steel column connections using the one-side bolts. All connections performed in the experiment were showed the strength up to 6%rad of the total rotation without the reduction of load capacity, but the stiffness and strength of the connections fell short of the rigid connection to be target capacity because the flexural deformation of the end-plate was early occurred. Thus the most critical element to be determined the performance of this connections is the thickness of end-plate. Also the new detail of connection to be addi-tionally installed at the inner side of the light-weight beam was proposed to improve the capacity of connection. |
Key Words:
Modular structure; One-side bolt; Beam-column connection; Cyclic load test |
요지 |
이 논문에서는 모듈화 구조에서 원사이드 볼트를 이용한 경량형강 보와 각형강관 기둥 접합부의 성능 분석을 위하여 반복가력실험을 실시하였다. 실험을 수행한 모든 접합부가 총 회전각 6% rad까지 하중의 감소 없이 성능을 발휘하고 있으나, 엔드플레이트가 초기에 휨 변형이 발생하여 접합부의 강성 및 내력이 목표성능인 강접합에 미치지 못하였다. 본 접합부에서 접합부의 성능을 결정짓는 가장 큰 요소는 엔드플레이트의 두께임을 실험을 통해 밝혀내었다. 또한 이 접합부의 성능 향상을 위해 원사이드 볼트를 경량형강 보의 내측으로 추가 설치할 것을 제안하였다. |
핵심용어:
모듈화 구조; 원사이드 볼트; 보-기둥 접합부; 반복가력실험 |