Abstract
This study introduces the estimation technique of tension force on elevator wire rope using measured frequencies. The proposed approach estimates tension force of elevator wire rope by appling the measured frequencies into the taut string theory or linear regression technique. Such frequencies are measured by accelerometers attached on elevator wire rope. To validate the proposed approach, the various experimental cases for real elevator wire ropes are conducted. The results reveal that both the taut string theory and the linear regression technique show an error bound of ${pm}10%$. Thus, in practice, the proposed approach could be used for the estimation of tension force on elevator wire rope.
Key Words: Natural Frequency; Elevator; Wire rope; Tension
요지
본 연구에서는 고유진동수를 이용하여 승강기 와이어 로프의 장력을 추정하는 방법에 대하여 소개한다. 제안 방법은 와이어로프의 진동수를 가속도계를 이용하여 계측하고 현이론법과 선형회귀법를 이용하여 장력을 추정하는 것이다. 제안 방법의 유효성을 검증하기 위하여 실물 승강기에 대하여 다양한 하중상태에 대하여 실험을 수행 하였다. 실험결과로부터 현이론법 및 선형회귀법 모두 오차범위 ${pm}10%$ 이내로 정확한 값을 추정할 수 있었으며, 제안 방법은 승강기 와이어로프 장력추정 실무에서의 적용이 가능성할 것으로 판단된다.
핵심용어: 고유진동수; 승강기; 와이어 로프; 장력


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
1010 New Bldg., The Korea Science Technology Center, 22 Teheran-ro 7-gil(635-4 Yeoksam-dong), Gangnam-gu, Seoul 06130, Korea
Tel: +82-2-567-6311    Fax: +82-2-567-6313    E-mail: master@kosham.or.kr                

Copyright © 2024 by The Korean Society of Hazard Mitigation.

Developed in M2PI

Close layer
prev next