원자로냉각재 펌프 주 플랜지 볼트 누설률 평가 |
조남진, 임석빈 |
|
The Evaluation for Leakage Rate of Reactor Coolant Pump Bolting in Nuclear Power Plants |
Nam Jin Cho, Seok Been Im |
|
|
|
Abstract |
In nuclear power plant, defected bolts used in the main flange of reactor coolant pump could have bad effect on the safety of the plant. Thus, the bolts should maintain their integrity while used in the plant. However, damaged bolts, such as corroded or cracked bolts, have been reported; thus, well-organized monitoring is required. This study evaluates safety of bolts currently used in a nuclear plant using the leakage rate. Using ANSYS program, the opening of a pump due to damaged bolts is estimated and corresponding leakage rate was estimated by SQUIRT code. The results exhibit that even in the case of 3 damaged bolts the leakage rate satisfies the allowable level, 1 gpm. However, continuous in-service inspection is still required to ensure the safety of bolts as considering the development of leakage rate. |
Key Words:
Reactor coolant pump; Leakage rate; ANSYS program; SQUIRT Code |
요지 |
원자력 발전소의 원자로 압력경계 기기 중에서 냉각재 펌프의 주 플랜지에 사용되는 볼트는 건전성이 상실될 경우, 발전소의 안전성에 영향을 미칠 가능성 있기 때문에 전 수명기간 동안 건전성이 보장되어야 한다. 하지만 이러한 볼트의 부식 및 균열에 대한 사례 보고가 있기에 이에 대한 체계적인 관리가 필요하다. 따라서 본 논문에서는 볼트의 손상으로 인해 발생하는 누설률을 통해 현재 가동 중인 발전소의 허용 안전성에 대해 알아보고자 한다. 볼트 손상에 따른 펌프의 간극을 수치해석 프로그램인 ANSYS를 사용하여 예측하고, 누설률 평가에는 SQUIRT 코드를 사용하여 평가하였다. 해석결과 볼트손상 수량이 3개일 경우에도 허용기준치인 1 gpm 이하인 것으로 판단된다. 비록 현재의 설계 볼트 수가 충분한 안전율을 확보한다고 판단되지만, 손상 볼트에 따른 누설률을 감았했을 때 지속적인 정기 점검을 통해 볼트의 건전도를 판단할 필요가 있다고 사료된다. |
핵심용어:
원자로냉각재펌프; 누설률; ANSYS 프로그램; SQUIRT 코드 |
|