유리섬유로 보강한 조적벽체의 전단내력식 설정에 관한 연구 |
권기혁, 이수철, 정원철 |
|
Proposing the Shear Force Equation of GFRP Strengthened Masonry Wall |
Ki-Hyuk Kwon, Soo-Chul Lee, Won-Chul Jung |
|
|
|
Abstract |
This study does by purpose that propose shear resisting force equation of reinforced masonry wall that is reinforced by GFRP(glass fiber reinforced polymer) based on result that is noted through cyclic loading of masonry wall and a shaking table experiment of mock that reflect identifying marks of masonry building which is constructed in domestic. It was Rocking mode to dominate failure of masonry wall in the experiment results, and the equations of UBC show the most resemblant value with experiment results. Through this study, propose the shear force equation of GFRP strengthened masonry wall as following. $$V_n=0.02A_n{sqrt{f`_m}}+0.022b_gh_g(1+2{alpha})^3{sqrt{f_g}}(N/mm^2)$$. |
Key Words:
GFRP; masonry building; masonry wall; shear strength; shear resisting force |
요지 |
본 연구는 국내에 시공된 조적조 건축물의 특징을 반영한 조적벽체의 반복가력과 모의진동대 실험을 통해 얻어진 결과를 근거로 하여 유리섬유로 보강된 보강조적벽체의 전단내력식을 제안하는 것을 목적으로 한다. 실험결과, 개구부가 없는 조적벽체의 파괴를 지배하는 모드는 Rocking이였고, 개구부가 있는 경우는 개구부 주변에 균열이 집중되었다. 비보강 조적벽체의 전단내력식은 UBC에서 제시한 식이 실험과 가장 유사한 값을 보였다. 본 연구를 통해 제안되어지는 유리섬유 보강조적벽체의 전단내력식은 다음과 같다. $$V_n=0.02A_n{sqrt{f`_m}}+0.022b_gh_g(1+2{alpha})^3{sqrt{f_g}}(N/mm^2)$$. |
핵심용어:
유리섬유; 조적조 건축물; 조적벽체; 전단강도; 전단내력 |