| SOS 보강장치의 체결 토크-우각부 압축 가압력 관계 및 반복하중 유지성능에 관한 실험적 연구 |
|
김대준1, 김대혁2, 이흥수3, 임정현4, 임남형5 |
1정회원, 한국수력원자력 고리1발전소 토건엔지니어링부 부장 2국가철도공단 철도혁신연구원 과장 3다음기술단 원자력사업부분 상무 4MIDAS IT 구조사업팀, 프로 5정회원, 충남대학교 공과대학 토목공학과 교수 |
| Experimental Study on Tightening Torque-Corner Compressive Pressure Relationship and Retention Performance of an SOS Reinforcement Device Under Cyclic Loading |
|
Dae Jun Kim1, Daehyeok Kim2, Heung Su Lee3, Jeong Hyeon Lim4, Namhyoung Lim5 |
1Member, General Manager, Structure Engineering, KORI Nuclear Power Plant, Korea Hydro & Nuclear Power Co., Ltd. 2Manager, Innovative Railway Research Institute, Korea National Railway 3Managing Director, Nuclear Power Business Division, Daum Engineering 4Pro, Structural Engineering Team, MIDAS IT 5Member, Professor, Department of Civil Engineering, Chungnam National University |
Corresponding author:
Namhyoung Lim, Tel: +82-42-821-7005, Fax: +82-42-825-0318, Email: nhrim@cnu.ac.kr |
|
Received: 10 September 2026 • Revised: 11 September 2026 • Accepted: 28 September 2026 |
|
|
| Abstract |
|
In this study, the compressive pressure at the corner region induced by the tightening torque of an SOS reinforcement system is evaluated, and the structural behavior of the specimen and reinforced member under cyclic loading is investigated. The compressive pressure increased with increasing tightening torque, while residual displacement and gradual hysteresis-loop widening were observed after the fourth cycle. In the ninth cycle, stiffness degradation occurred, with a maximum displacement of approximately 19 mm and a residual displacement of approximately 4 mm. Despite the progressive damage to the specimen, the axial strain of the SOS member showed no abrupt relaxation, indicating that the initial prestress of the device was retained within the tested load range. |
| Key Words:
SOS Reinforcement Device, Pressure Force, Underground Concrete Box Structure, Four-point Loading Test, Haunch |
| 요지 |
|
본 연구에서는 SOS 보강장치의 체결 토크에 따른 우각부 압축 가압력과 반복재하에 따른 시험체 및 보강장치의 구조 거동을 평가하였다. 체결 토크가 증가할수록 우각부 가압력이 증가하는 경향을 확인하였으며, 반복재하 과정에서 4사이클 이후 잔류변위와 이력루프가 점진적으로 증가하였다. 9사이클에서는 강성 저하와 함께 최대변위 약 19 mm, 잔류변위 약 4 mm가 나타났다. 시험체의 손상이 진행되는 동안에도 SOS 부재의 축변형률은 급격한 이완 없이 유지되어, 본 실험 범위에서 보강장치에 도입된 초기 가압력이 유지됨을 확인하였다. |
| 핵심용어:
SOS 보강장치, 가압력, 지중 콘크리트 박스구조물, 4점 재하실험, 우각부 |
|