J. Korean Soc. Hazard Mitig Search

CLOSE


J. Korean Soc. Hazard Mitig. > Volume 25(5); 2025 > Article
실무적 활용성 증대를 위한 상수관망 관세척 등급 평가 방법론 개발 및 적용

Abstract

To ensure a stable supply of potable drinking water, effective management of the distribution system, starting from the reservoir to the consumer water-supply facility, is essential. Following the 2019 flood in Incheon Metropolitan City, Korea has mandated that transmission and distribution pipelines be cleaned at least once every 10 years. However, budgetary and management constraints make it difficult to clean all pipelines, especially in complex underground water supply systems spanning vast areas. This study evaluated seven cleaning-grade criteria proposed in previous studies for a medium-sized block in one region of Korea, and compared the rating results based on different combinations of these criteria. Additionally, a grouping-based assessment based on flow direction was performed to propose a feasible rating method. The findings revealed that methodologies from previous studies tended to apply overly strict criteria for cleaning grades, overlooking potentially hazardous pipelines that could lead to water quality accidents. Furthermore, using a cross-sectional evaluation criterion, without clearly established weights for each of the seven application criteria, is limited as it fails to consider potential risks. Therefore, prioritizing the weighting of individual criteria and conducting a group-based evaluation that facilitates practical judgment can support the development of a mid- to long-term pipeline maintenance plan.

요지

먹는 물에 적합하도록 정수한 물을 소비자에게 적정한 수질로 공급하기 위해서는 배수지로부터 소비자 급수시설까지 공급되는 단계인 배수시스템의 안정적 관리가 매우 중요하다. 2019년 발생된 인천광역시의 적수사고를 계기로, 국내의 경우 송배수관로의 관세척을 10년에 1회 이상으로 실시하도록 규정하고 있다. 그러나 매우 방대한 지역에 걸쳐 복잡하게 땅속에 얽혀있는 상수도관로 시스템의 경우 예산 및 관리여건의 제약에 따라 모든 관로를 규정에 맞게 세척하기에는 어려움이 있다. 본 연구에서는 선행연구 등에서 제시된 관세척 등급을 위한 7가지 기준에 대하여 국내 1개 지역의 중블록을 대상으로 평가하고, 기준의 조합방법에 따른 등급평가 결과에 대한 비교분석을 실시하였다. 추가적으로 유향방향의 그룹화 기반의 평가를 수행하여, 실무적으로 실현가능한 등급평가 방안을 제시하고자 하였다. 적용 및 분석 결과 기존의 선행 연구에서 제시된 방법론은 관세척 등급평가 기준을 매우 엄격하게 제시하는 경향이 있어 수질사고를 유발할 수 있는 잠재적 위험관로를 놓칠수 있음이 확인되었다. 또한 7가지 적용기준 별 가중치가 명확히 정립되지 않은 상황에서 교집합적 평가 기준을 제시하는 것은 잠재적 위험성을 고려하지 않는다는 한계점을 가진다 평가할 수 있다. 따라서 개별적 기준에 대한 가중치를 우선 동일하게 하여 평가하고, 실무적 판단을 용이하게 할 수 있는 그룹기반의 평가를 수행하는 것이 단, 중장기 관세척 계획을 수립하는데 기여할 수 있다고 판단된다.

1. 서 론

2019년 발생된 인천광역시 붉은 수돗물 사태로 관할 급수구역에 포함된 26만 1천 세대, 63만 5천 명이 직간접적인 피해를 입었다. 상수관망 내 수질사고 발생을 원천척으로 막는데에는 한계가 있으므로, 수질사고 발생 시 그 피해를 최소화 할 수 있는 전략연구는 반드시 필요하다. 2021년 2월, 상수도관망의 운영 및 관리 체계를 강화하고 수돗물 안전을 확보하기 위하여 일반수도사업자의 상수도관망 세척 의무화가 시행되었다. 이와 같은 세부기준을 충족, 이행하기 위해서는 중장기 계획 기반의 연차별 관세척 시행계획을 수립하는 것이 궁극적으로 필요하며, 계획 수립을 위해서는 상수관로 별 상태평가를 수행하고 평가 기준에 따른 정량적 관세척 등급 평가가 우선적으로 필요하다.
상수도관망의 효율적 운영과 체계적인 유지관리를 위한 연구는 국내외적으로 다양한 방법으로 활발히 수행되고 있다. 효율적이며 체계적인 운영 및 유지관리가 되기 위해서는, 물공급의 역할을 담당하는 관로의 상태평가가 필수적이다. 현재까지의 국내외의 연구는 대부분 관로의 교체 또는 개량을 위한 관 상태평가 또는 시스템의 성능평가(Choi et al., 2024) 중심으로 연구가 진행되어왔다. 교체 또는 개량은 기존 관로를 폐기하고 새로운 관을 시공(교체)하거나 다양한 방법을 통해 노후화된 관로의 기능을 대부분 회복(개량)하는 방법을 의미한다. 따라서 관로의 일상적 유지보수를 의미하는 관세척(Cleaning)에 관한 연구는 관세척 기법과 수리학적 평가에 대한 주제를 중심으로 일부만 수행되었다. 대부분의 관세척 연구는 소화전의 운용에 기반한 물세척(플러싱, Flushing)관련 연구라 할 수 있다.
Ahn et al. (2008)은 플러싱의 도입을 위해 플러싱에 의한 세척시 수리학적 및 수질적 특성을 세척수 유속 측정 및 수질평가 등을 통해 평가하였다. Bae et al. (2015)은 상수관망에서의 소화전 개방에 따라 도출되는 세척수의 유속에 따른 세척효과를 평가하여 자가세척이 가능한 유속을 제안하는 연구를 수행하였다. Kim et al. (2020)은 플러싱 공법의 적용과 효과성 극대화를 위하여 플러싱 적정구역을 정의하고 적정유속 확보여부의 평가를 위한 수리적 해석 방법을 제안하는 연구를 수행하였다. Hong et al. (2021)은 플러싱의 소블럭별 효과를 정량적으로 평가하기 위하여 소블럭 내 소화전 설치 밀도와 개방 순서를 조정하여 관세척 효과를 정량적 수리해석기법으로 모의분석하였다. Lee et al. (2025)은 DEA (Data Envelopment Analysis)를 활용하여 정상상황에서 관 내 퇴적의 영향을 고려한 ‘퇴적위험관’과 비정상상황에서 비상관을 사용하는 비상시 수계전환 시나리오를 기반으로 한 ‘박리위험관’을 선정하여 플러싱 우선순위를 보다 정량적을 도출할 수 있는 방안을 제시하였다. 한국상하수도협회는 2021년 「상수도관망 세척 매뉴얼(KWWA, 2021)」을 통해, 유속, 체류시간, 잔류염소, 세척이력 등 총 7가지 수리⋅수질⋅물리적 요소를 기반으로 관 상태등급(I~IV)을 산정하고, 등급별로 세척주기를 차등화하는 평가체계를 제시하였다. 이와 같은 7가지 기준은 대상지역의 상수관망 수리해석 결과와 유지관리 이력 등의 다양한 정보를 활용한다는 측면에서 활용가치가 높고 객관적인 등급평가가 될 수 있다는 장점을 가진다. 다만, 7가지 기준의 교집합을 통하여 위험관로를 제시하는 체계를 따르고 있어, 7가지 항목에 대한 만족이 모두 되지 않는 상황에서만 수질적 문제를 야기할 수 있는 관로로 등급구분이 된다는 특징이 있다. 이와 같은 교집합 기반의 등급 평가 방식은 방대한 구간의 관로에서 특징적 위험관로를 식별하는데에는 유용할 수 있지만, 전체적인 관세척 우선순위를 평가하는데에는 효과적이지 않을 수 있다.
국외의 경우 Alfonso et al. (2010)은 최적화 기법을 활용하여 오염물질 유입 등의 긴급상황에서의 플러싱 위치, 시간, 유량 등을 변수로 고려한 최적 플러싱 전략을 제안하였으며, Shafiee and Berglund (2015)는 소화전에 부착하는 센서장치를 활용하여 의사결정 트리를 결합한 실시간 플러싱 운영체계를 구현하는 실무적 연구를 수행한 바 있다.
본 연구에서는 선행연구 등에서 제시된 관세척 등급을 위한 7가지 기준에 대하여 국내 1개 지역의 중블록을 대상으로 평가하고, 기준의 조합방법에 따른 등급평가 결과에 대한 비교분석을 실시하였다. 추가적으로 유향방향의 그룹화 기반의 평가를 수행하여, 실무적으로 실현가능한 등급평가 방안을 제시하고자 하였다.

2. 방법론

2.1 연구지역 및 관세척 등급 평가 기준인자

본 연구에서 제안한 방법론을 국내의 소도시라 할 수 있는 장흥군 상수관망시스템에 적용하였다. 장흥군의 총면적은 622.4 km2로 3읍, 7면으로 구성되어 있다. 장흥군 상수관망은 9개의 중블록으로 구성되어 있으며, 이 중 Fig. 1과 같은 관산 중블록을 대상으로 방법론을 적용하여 평가하였다.
Fig. 1
Network Map of Study Area
kosham-2025-25-5-79-g001.jpg
본 연구에서는 KWWA (2021)에서 제시된 관세척을 위한 상수관로의 7가지 평가기준을 준용하여기본평가를 수행하였다. 7가지 기준은 Table 1과 같이 평균유속, 체류시간, 경년관, 비내식성관로, 수질민원, 잔류염소기준, 그리고 세척이력으로 구성된다. 해당기준에서는 각 항목별 판단기준을 Table 1과 같이 제시하고 있으나, 이와 같은 정량적 기준은 수도사업자가 반드시 따라야 할 의무규정은 아니며, 상수관망의 현황, 매설환경 등에 따라 적정히 조정될 수 있다. 그러나, 이와 같은 7가지 기준은 관내 침전물이 쌓이고, 잠재적 수질문제를 야기할 가능성이 있는 인자로 관세척 여부 평가를 위해 필요한 정량적 인자라 할 수 있다. KWWA (2021)에서는 7가지 인자의 평가가 수행되면 Fig. 2와 같이 7가지 인자의 공통적 만족여부 등을 고려한 교집합기반의 등급구분을 제안하고 있다. 관 세척을 위해 7개 기준을 평가하는 것은 타당하나, 7개 기준 인자가 모두 만족되어야만 취약관로로 구분되며, 평균유속과 체류시간이 우선적인 중요인자로 고려되어 필수적으로 세척이 필요한 구간(예, 수질민원 다발 구간) 등이 누락될 가능성이 있다. 이와 같은 기준을 적용하게 되면 매우 낮은 취약관로 비율의 선정에 따라, 상수도시스템의 노후정도, 사업자의 관망관리 환경 등이 반영된 합리적인 세척을 위한 관상태 평가가 어려울 수 있다.
Table 1
7 Evaluation Items and Judgment Criteria (Example)
Items Judgment Criteria (Example) Description
Average Velocity Less than 0.07 m/s Lower flow rates increase the likelihood of sedimentation and stagnation
Travel Time More than 120 hours Longer retention times can lead to decreased residual chlorine and deteriorated water quality
Aging Pipe More than 20 years from the date of installation, etc. Long-term buried pipes are susceptible to corrosion and sediment accumulation
Non-corrosive pipe SP, PVC pipe, etc. Low durability increases the risk of internal corrosion and delamination
Water quality complaints Whether or not there has been a recent complaint Cleaning is required if complaints arise regarding water quality, such as turbidity or foreign matter
Residual chlorine standards Less than 0.1 mg/L If the water quality falls below the standard, there is a risk of bacterial growth
Cleaning history Whether there is a history of cleaning within the past 10 years Recent cleaning is a key indicator of pipe maintenance
Fig. 2
Intersection-Based Grade Evaluation (KWWA, 2021)
kosham-2025-25-5-79-g002.jpg

2.2 연구흐름

본 연구에서는 Fig. 3과 같은 연구흐름도를 제안하였다. 우선, 관망의 지리정보시스템에서 제시하고 있는 관로의 물리적 빅데이터정보와 수리 및 수질해석 결과를 활용하여 선행연구에서 제안된 7가지 관세척 평가인자를 도출한다. 7가지 개별 평가인자의 결과를 기존의 KWWA (2021)에서 제시된 방법과 같이 교집합 중심의 등급구분 방안을 적용하여 평가하고, 충족개수 기반의 등급구분 방안을 추가적으로 적용하여 그 결과를 비교평가한다. 충족개수 기반의 등급구분은, 특정 항목의 과도한 영향력을 배제하고, 다양한 위험 요인을 균형 있게 반영할 수 있는 평가체계를 마련하고자 7가지 평가 항목을 동일한 가중인자를 갖는다고 간주하여, 0-1개의 항목이 충족될 경우 I 등급, 2-3개의 항목이 충족될 경우 II등급, 4-5개의 항목이 충족될 경우 III등급, 그리고 6-7개의 항목이 충족될경우에는 IV등급으로 구분하였다.
Fig. 3
Study Flowchart
kosham-2025-25-5-79-g003.jpg
추가적으로 충족개수 기반의 등급구분 방안의 결과를 활용하여 개별관로 별로 관세척을 실시하는 것은 실무적 효용성이 떨어지므로, 수리해석에 기반한 관로별 유향을 고려하여 적정한 그룹으로 관로를 그룹화 한다. 이후 단일 그룹으로 구분된 지역의 개별관로의 관세척 등급을 평균하여 그룹별 관세척 등급을 산정하여 그 결과를 제시한다.

3. 적용 및 결과

3.1 대상지역 수리 및 수질해석 수행 및 유향방향 그룹화

Fig. 4는 본 연구에서 적용한 대상 중블록의 수리 및 수질해석 결과의 분포도를 나타낸 것이다. 유속의 경우 상수관망시스템의 말단부분에서 0.07 m/s 이하의 값으로 저유속구간이 다수 나타나는 것을 확인할 수 있으며, 잔류염소농도의 경우에도 관로시스템 말단부분에서 0.2 mg/L 이하의 값으로 낮게 나타나는 것을 알 수 있다. 이와 같은 수리적 특성에 따라 배수지로부터 공급된 물의 관로내 체류시간이 일부구간의 경우 96시간 이상 나타나는 것을 확인할 수 있다.
Fig. 4
Results of Hydraulic and Water Quality Analysis
kosham-2025-25-5-79-g004.jpg
이와 같은 수리해석 및 수질해석의 결과에 따라, 본 연구대상지역의 관세척을 위한 등급평가의 세부기준을 Table 2와 같이 결정하여 기준 만족여부를 평가하였다. 평균유속 평가기준은 0.07 m/s, 체류시간 기준은 72시간으로 하였으며, 잔류염소기준의 경우 법적 최하기준인 0.1 mg/L로 설정하여 평가하였다.
Table 2
7 Evaluation Items and Judgment Criteria (Study Area)
Items Judgment Criteria
Average Velocity Less than 0.07 m/s
Travel Time More than 72 hours
Aging Pipe Cast iron, steel, and stainless steel pipes: 30 years PVC and PE pipes (non-metallic): 20 years
Non-corrosive pipe Cast iron, steel, and stainless steel pipes: Non-corrosive PVC and PE pipes (non-metallic): Corrosion-resistant
Water quality complaints Derivation of complaints and damaged sections
Residual chlorine standards Less than 0.1 mg/L
Cleaning history Sections where old pipe cleaning is not implemented
Fig. 5는 수리해석의 결과에 따라 도출된 관로의 유향방향을 고려하여, 9개의 대그룹으로 구역을 구분한 결과를 나타내고 있다. 대상지역의 경우 수지상식 관로시스템을 보이고 있어, 특정적인 분할 알고리즘을 활용하지 않더라도, 실무적 적용성을 증대시키기 위하여 Fig. 5와 같이 적정하게 구역을 분할 할 수 있다. 본 연구에서는 9개의 대구역을 다시 각각 13(A1), 3(A2), 1(B), 2(C), 3(E1), 19(E2), 9(F), 12(G), 그리고 4(GW)개의 총 66개 소구역으로 구분하여 평가를 실시하였다.
Fig. 5
Results of Group Classification Considering Flow Direction
kosham-2025-25-5-79-g005.jpg

3.2 개별관로별 관세척을 위한 관로상태등급 산정결과

KWWA (2021)의 기준에 따른 상태등급 분포를 분석한 결과는 Table 3과 같다. 전체 관로의 93.55%가 Ⅰ등급으로 분류되었으며, 총연장 기준에서도 92.78%를 차지하여 대부분의 관로가 양호한 상태로 평가되었다. Ⅱ등급은 5.92% (연장 7.13%) 수준으로 일부 구간에 국한되었으며, Ⅲ⋅Ⅳ등급은 관로수 기준 0.52%, 연장 기준 0.1% 이하로 나타나 고위험 구간의 비중은 사실상 미미하였다.
Table 3
Results of Calculating the Pipeline Condition Grade based on KWWA Standards
Condition Grade Number of Pipes Total Length (m) Pipeline Number Ratio (%) Extension Ratio (%)
Ⅰ 537 64,649.1 93.56 92.779
Ⅱ 34 4,964.9 5.92 7.125
Ⅲ 2 65.6 0.35 0.094
Ⅳ 1 1.39 0.17 0.002
이와 같은 결과는 KWWA (2021)의 기준이 위험 요인 반영에 있어 상대적으로 보수성이 결여되어 있음을 시사한다. 특히 고위험 관로가 극소수로 산정된 것은 본 기준이 실제 현장에서의 잠재적 취약성과 사고 가능성을 충분히 포착하지 못하고 있음을 의미한다. 따라서 환경부 기준만으로는 위험 기반 유지관리 전략 수립에 한계가 존재하며, 이를 보완하기 위한 대안적⋅정밀화된 평가 방법론의 도입 필요성이 뚜렷하게 제기된다.
충족개수 기준 관로상태등급 산정결과는 Table 4와 같다. 전체 관로 중 Ⅰ등급은 308개(53.66%), 총연장 기준으로 58.76%를 차지하여 가장 큰 비중을 보였다. 이어서 Ⅱ등급은 236개(41.11%), 총연장 37.53%로 나타나, 상당수의 관로가 환경부 기준보다 한 단계 높은 위험도로 재분류되었다. 반면, Ⅲ등급은 27개(4.70%), 연장 3.61%, Ⅳ등급은 3개(0.52%), 연장 0.10%로 나타났다. 이러한 결과는 KWWA (2021)의 기준과 달리 가중치 방법론이 상대적으로 위험 요인을 강화 반영하고 있음을 보여준다. 특히, Table 5와 같이 기존 기준에서 대부분 Ⅰ등급으로 분류되었던 관로들이 상당 부분 Ⅱ등급으로 이동하면서, 잠재적 위험성을 보다 명확히 드러내는 효과가 나타났다. 이는 곧 가중치 방법론이 위험 관리 중심의 유지관리 전략 수립에 더 적합하며, 고위험 관로를 선별하고 중위험 구간을 관리대상으로 설정하는 데 기여할 수 있음을 알수 있다. Fig. 6은 KWWA 기준(ENV, Flowchart)과 충족개수-동일가중치기준(Weighted, Count-based)에 따라 산정된 관로 상태등급 분포를 비교한 것이다. Figs. 7, 8은 각 세척 평가 항목 기준에 미달된 경우에 해당하는 관로의 등급 분포를 그래프로 나타낸 것이다. KWWA (2021)의 방법의 경우 대부분의 요인에서 Ⅰ등급(하늘색)과 Ⅱ등급(연두색)에 집중되는 양상을 보였으며, Ⅲ⋅Ⅳ등급(주황⋅빨강)은 소수에 불과하였다. 이는 환경부 기준에 세척등급 분류가 특정 요인을 보수적으로 평가하여 관로 상태를 주로 낮은 위험 등급에 몰아넣는 경향이 있음을 보여준다. 따라서 환경부 기준만으로는 실제 취약 요인을 충분히 반영하기 어렵다는 한계를 확인할 수 있다.
Table 4
Results of Calculating the Pipeline Condition Grade based on the Number of Satisfactions
Condition Grade Number of Pipes Total Length (m) Pipeline Number Ratio (%) Extension Ratio (%)
Ⅰ 308 40,941.45 53.66 58.76
Ⅱ 236 26,154.66 41.12 37.53
Ⅲ 27 2,518.70 4.70 3.61
Ⅳ 3 66.22 0.52 0.10
Table 5
Analysis of Changes in Condition Ratings for Two Methodologies
KWWA (2021) No. of Satisfaction-based
Ⅰ Grade (%) Ⅱ Grade (%) Ⅲ Grade (%) Ⅳ Grade (%)
Ⅰ Grade 57.36 38.73 3.91 0.00
Ⅱ Grade 0.00 82.35 14.71 2.94
Ⅲ Grade 0.00 0.00 50.00 50.00
Ⅳ Grade 0.00 0.00 0.00 100.00
Fig. 6
Grade Distribution Results according to Two Grade Classification Criteria
kosham-2025-25-5-79-g006.jpg
Fig. 7
Distribution of Grades by Evaluation Factor according to the KWWA (2021) Method
kosham-2025-25-5-79-g007.jpg
Fig. 8
Distribution of Grades by Evaluation Factor according to the Method based on the Number of Satisfactions
kosham-2025-25-5-79-g008.jpg

3.3 그룹화 적용 절차 및 기준

본 연구는 관세척의 실무적 효율성을 높이기 위해 유향(물의 흐름 방향)을 기준으로 관로를 그룹화 하였다.
먼저, 상수관망의 수리 해석 결과를 바탕으로 물의 큰 흐름에 따라 관로망을 9개의 대그룹으로 분류했습니다. 이어서 대그룹 내에서 유향이 일관된 구간을 기준으로 소구역을 세분화했다.
최종적으로, 각 소구역에 속한 개별 관로들의 관세척 등급을 평균하여 해당 구역의 대표 등급을 산출 하였다.

3.4 그룹별 상태등급 산정 결과

그룹을 대상으로 KWWA (2021)과 기준(ENV, 파란색)과 가중치 기준(WGT, 주황색)의 평균등급을 비교한 결과는 Fig. 9와 같다. 기존 기준에서는 대부분 그룹이 Ⅰ등급으로 분류되어 전반적으로 안정적인 상태를 보였으나, 충족개수 기반 기준에서는 다수의 그룹이 Ⅱ⋅Ⅲ등급으로 이동하며 평균등급이 상승하였다. 특히 E1 계열(E1-1, E1-2, E1-3)과 E2 초기 그룹(E2-2, E2-4, E2-6, E2-11, E2-12, E2-14 등)에서 위험도가 크게 높아지는 양상이 나타났다. 이는 기존 기준이 상대적으로 보수적인 분류를 통해 안정성을 강조하는 반면, 충족개수 기준은 세부 조건과 가중치를 반영하여 잠재적인 위험 요인을 민감하게 포착했음을 의미한다. 따라서 충족개수 기반 기준은 중⋅고위험 후보군을 조기에 식별하고 유지관리 우선순위를 설정하는 데 유리한 결과를 보여준다.
Fig. 9
Group-based Average Grade Distribution by Group
kosham-2025-25-5-79-g009.jpg
E2 후반부(E2-16, E2-18, E2-22, E2-26)와 F 계열(F-2, F-4, F-6, F-8, F-9)에서 평균등급 상승 폭이 컸다. G 계열에서도 일부 그룹(G-3, G-6, G-11, G-14, G-15)이 기존보다 높은 등급으로 이동하여, 잠재 위험이 과소평가될 수 있음을 확인할 수 있었다. 반면 GW 계열과 일부 G 그룹(G-4, G-8, G-10, G-12)은 변화가 거의 없거나 Ⅰ등급을 유지하였다. 이러한 결과는 충족개수기반 기준이 기존기준보다 관로 상태를 더 세밀하게 평가하여 중⋅고위험 관로를 적극적으로 식별함을 보여주며, 실제 유지관리 전략 수립 시 충족개수 기준의 활용성이 크다는 점을 알수 있다.

4. 결 론

본 연구는 기존 평가 방식의 한계를 보완하는 충족 개수 기반의 평가 방안을 제시함으로써, 중⋅고위험 관로를 효과적으로 식별하고 효율적인 관세척 계획을 수립하는 데 기여할 수 있음을 입증했다. 추가적으로 유향방향의 그룹화 기반 평가를 수행하여, 실무적으로 실현 가능한 등급평가 방안을 제시하고자 하였다. 적용 및 분석 결과 기존 선행연구에서 제시된 방법론은 관세척 등급평가 기준을 매우 엄격하게 제시하는 경향이 있어 수질사고를 유발할 수 있는 잠재적 위험관로를 놓칠 수 있음이 확인되었다. 또한 7가지 적용기준별 가중치가 명확히 정립되지 않은 상황에서 교집합적 평가 기준을 제시하는 것은 잠재적 위험성을 고려하지 않는다는 한계점을 가진다고 평가할 수 있다. 따라서 개별 기준에 대한 가중치를 우선 동일하게 하여 평가하고, 실무적 판단을 용이하게 할 수 있는 그룹 기반 평가를 수행하는 것이 중⋅장기 관세척 계획을 수립하는 데 기여할 수 있다고 판단된다.
그러나 본 연구에서는 관세척 평가 기준 인자 간의 상대적 중요도를 고려하지 않고 동일한 가중치를 부여했다는 한계가 존재한다. 향후 연구에서는 계층적 분석법(AHP)이나 기계학습(Machine Learning) 기법 등을 활용하여 각 평가 인자의 최적 가중치를 도출하는 심층적인 연구가 필요하며, 이를 통해 모델의 정확도를 높이고 상수도관망의 선제적 유지관리 체계를 한 단계 더 발전시키는 데 기여할 수 있을 것이다.

감사의 글

본 연구는 환경부의 재원으로 한국환경산업기술원의 가뭄대응 물관리 혁신기술개발사업의 지원을 받아 연구되었습니다(RS-2023-00231944).

References

1. Ahn, J.C, Lee, S.W, Baek, K.I, Choi, Y.J, Choi, J.H, Jeong, E.S, et al (2008). Hydraulics and water quality characteristics of flushing in distribution pipes. J. Korean Soc. Water Wastewater, Vol. 22, No. 1, pp. 93-22.

2. Alfonso, L, Jonoski, A, and Solomatine, D (2010). Multiobjective optimization of operational responses for contaminant flushing in water distribution networks. Journal of Water Resources Planning and Management, Vol. 136, No. 1, pp. 48-136.
crossref
3. Bae, C.H, Lee, D.J, Choi, D.Y, Jun, H.J, Park, S.H, and Choi, T.H (2015). An assessment of the effect of air scouring and swabbing pig cleaning technique on water distribution pipes. Journal of Korean Society of Water and Wastewater, Vol. 29, No. 4, pp. 459-29.
crossref
4. Choi, Y.H, Kim, M.J, and Kim, T.G (2024). Development of a machine-learning-based framework to assess the performance of water distribution systems. J. Korean Soc. Hazard Mitig, Vol. 24, No. 5, pp. 49-24.
crossref pdf
5. Hong, S, Joo, J.G, Lee, S, and Yoo, D.G (2021). Flushing effect depending on the installation density and opening order of fire hydrants in water supply networks. Journal of the Korean Society of Hazard Mitigation, Vol. 22, No. 1, pp. 163-22.
crossref pdf
6. Kim, S, Gim, A, Ha, J, Kim, J, and Jun, H (2020). A study on the delineation of flushing sections and simulation method to verify appropriate flushing velocity for applying flushing. Journal of the Korean Society of Hazard Mitigation, Vol. 20, No. 5, pp. 255-20.
crossref pdf
7. Korean Water &Wastewater Association (KWWA) (2021). Manual for cleaning water distribution networks. Seoul, Korea.

8. Lee, S.I, Kim, J, Kim, A, and Jun, H (2025). Risk pipe assessment and flushing block prioritization in water distribution networks based on DEA. Journal of the Korean Society of Hazard Mitigation, Vol. 25, No. 3, pp. 85-25.
crossref pdf
9. Shafiee, M.E, and Berglund, E.Z (2015). Real-time guidance for hydrant flushing using sensor-hydrant decision trees. Journal of Water Resources Planning and Management, Vol. 141, No. 6, pp. 04014079.
crossref


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
1014 New Bldg., The Korea Science Technology Center, 22 Teheran-ro 7-gil(635-4 Yeoksam-dong), Gangnam-gu, Seoul 06130, Korea
Tel: +82-2-567-6311    Fax: +82-2-567-6313    E-mail: master@kosham.or.kr                

Copyright © 2026 by The Korean Society of Hazard Mitigation.

Developed in M2PI

Close layer
prev next